INNITIUS

Ultrasound examination during pregnancy for preterm labor assessment

Fetal Fibronectin Test: Clinical Use, Accuracy, and Role in Threatened Preterm Labor

Rubén Molina
Rubén Molina CEO & Co-founder

Threatened preterm labor is one of the most frequent and most difficult triage scenarios in obstetric units. Women presenting with preterm contractions and intact membranes require a prompt decision on admission, antenatal corticosteroids, or tocolysis.

For over two decades, the fetal fibronectin (fFN) test has been one of the main tools used to separate these two groups. Since Hologic withdrew its Rapid fFN 10Q quantitative assay from sale worldwide in September 2024, it is worth reviewing how the test works, what its accuracy data show, and where clinical practice may be heading with potential alternatives.

 

Fetal Fibronectin Testing in Clinical Practice: Current Protocols

 

fFN is an extracellular matrix glycoprotein found at the maternal–fetal interface, where it acts as an adhesive between the fetal membranes and the decidua. It is normally present in cervicovaginal fluid early in pregnancy, but after 22 weeks its concentration usually falls below 50 ng/mL. Its reappearance is thought to reflect inflammatory, infectious, or mechanical damage in this interface, and its presence at higher concentrations than 50 ng/mL between weeks 22 and 35 is associated with a high risk of subsequent preterm labor.


Newborn infant receiving hospital care after preterm birth

 


The sample is collected during a speculum examination by placing a swab in the posterior vaginal fornix for about 10 seconds, always before any digital examination. It is then analyzed with a bedside immunochromatographic test strip read by an automated analyzer that reports the actual concentration.

Eligibility criteria differ between guidance documents. As an example, in the UK the London Maternity Strategic Clinical Network (NHS) recommends testing symptomatic women between 22 and 35 weeks with intact membranes and cervical dilatation below 3 cm, whereas the National Institute for Health and Care Excellence (NICE) positions fFN from 30+0 weeks as an alternative when transvaginal cervical length measurement is not available or acceptable, using a 50 ng/mL cutoff.

Accuracy and Predictive Value: What the Evidence Says About fFN

 

The clinical value of fFN rests on its negative predictive value (NPV). In symptomaticwomen, a negative result carries an NPV of 99.2% for delivery within 14 days, which means that it is highly unlikely that a woman’s symptoms of preterm labor will result in delivery within the next 14 days. This supports safe discharge and helps avoid unnecessary hospitalization, untimely corticosteroid use, and maternal anxiety.

On the contrary, its positive predictive value (PPV) remains below 30% in both symptomatic and asymptomatic populations, so most women with a positive result will not deliver in the days that follow. Data from a Spanish level-III hospital retrospective study in 378 eligible patients, in which 2.6% of women delivered spontaneously within 7 days, showed that qualitative fFN had an NPV of 97.9% but a PPV of only 7.9% (Melchor et al., 2018).

Quantitative measurement partially corrects this imbalance. The EQUIPP study demonstrated that quantitative fFN provides thresholds in addition to the qualitative method (50 ng/mL) to discriminate the risk of spontaneous preterm birth in symptomatic women. Raising the threshold from 10 to 50, 200, or 500 ng/mL increased the PPV for delivery before 34 weeks from 19% to 32%, 61%, and 75%, respectively (Abbott et al. 2013).

 

 

Limitations of fFN Testing: Where the Test Falls Short

 

The low PPV has direct consequences at the bedside. False-positive results lead to admissions, tocolysis, and corticosteroid courses that may not be needed. In this situation, timing is crucial, since the neonatal benefit of steroids is concentrated in infants born within 7 days of administration. For this reason, the American College of Obstetricians and Gynecologists (ACOG) advises against using a positive fFN result alone as a predictor of preterm birth.

The test is also susceptible to pre-analytical interference. Sexual intercourse within the previous 48 hours, vaginal bleeding, ruptured membranes, and recent cervical manipulation can all produce false-positive or invalid results, and NICE discourages its independent use in twin pregnancies.

Availability has now become an additional constraint. In July 2024, Hologic announced the cessation of production of its Rapid fFN 10Q quantitative cassettes, the quantitative fetal fibronectin test mostly used in clinical practice. Because the fFN platform is no longer available, leading health organizations, such as NHS England and the Royal Australian and New Zealand College of Obstetricians and Gynaecologists (RANZCOG), have advised maternity units to transition to alternative biomarkers:

  • Actim® Partus: A rapid vaginal swab test that detects insulin-like growth factor binding protein-1 (phIGFBP-1).
  • PartoSure®: A rapid diagnostic test that detects placental alpha microglobulin-1 (PAMG-1).

 

Combining fFN with Cervical Length Measurement: Clinical Decision Pathways

 

Combining fFN with transvaginal cervical length (CL) has been proposed as an alternative to compensate for the weaknesses of each test. A systematic review of nine studies in symptomatic women found that, for delivery within 7 days, the combined approach reached a sensitivity of 71.4%, a specificity of 96.8%, and an NPV of 98.9%, although the PPV remained modest at 45.4%; this estimate, however, was pooled from only two studies and 192 women (DeFranco et al., 2013). Guidance is not uniform, however, as NICE explicitly recommends against using CL and fFN in combination to diagnose preterm labor in the Preterm labor and birth guideline (NG25).

The QUiPP app extends this logic by integrating quantitative fFN, CL, and clinical risk factors into an individualized risk estimate. In the EQUIPTT cluster randomized trial, it achieved an AUC of 0.90 for delivery within 7 days, although the reduction in admissions compared with standard care did not reach statistical significance (7.4% vs 9.9%) (Watson et al., 2021).

 

Beyond fFN: Emerging Cervical Assessment Technologies for Obstetric Units

 

Among biochemical alternatives, PAMG-1 has shown an advantage in positive prediction. Comparing two one-year periods at the same hospital, Melchor et al. (2018) reported a PPV of 35.3% for PAMG-1 versus 7.9% for fFN for delivery within 7 days, with a comparable NPV (98.3% vs 97.9%). Like the other available alternatives, however, PAMG-1 provides only a qualitative result.

Biomarkers detect the biochemical consequences of membrane disruption rather than the mechanical state of the cervix. Cervical remodeling involves changes in the tissue itself, as collagen content decreases and hydration increases, and these changes alter cervical consistency before shortening becomes measurable. Stiffness captures a mechanical process that biomarkers do not assess and that precedes the anatomical change detected by cervical length, providing an alternative measurement to detect preterm labor.

CerviSense, developed by Innitius, was designed to provide this measurement at the point of care through torsional wave elastography (TWE). Unlike ultrasound elastography, TWE does not rely on imaging: a CE-marked intravaginal probe in direct contact with the cervix uses an electromechanical actuator to propagate a torsional wave through the tissue, and its sensor system captures how that wave is distorted to calculate the cervix’s shear modulus, a stiffness value in kilopascals obtained in real time. This value is combined with clinical parameters using condition-specific AI models. The clinician obtains an actionable input to support triage decisions for women presenting with threatened preterm labor symptoms.

The reliability of the measurement has been established in a multicenter study of 77 singleton pregnancies in five Spanish hospitals, which showed excellent interobserver reproducibility (ICC 0.93). The threatened preterm labor application is currently under clinical validation, and we are now running a clinical trial across 18 sites in Germany and Spain to assess whether the device can predict spontaneous preterm birth within 7 days.

 

Innitius CerviSense torsional wave elastography probe for cervical stiffness assessment

 

Learn more about CerviSense

Sources

Abbott DS et al. Evaluation of a quantitative fetal fibronectin test for spontaneous preterm birth in symptomatic women. Am J Obstet Gynecol. 2013 Feb;208(2):122.e1-6. doi: 10.1016/j.ajog.2012.10.890.

Creswell L et al.Preterm Birth: Screening and Prediction. Int J Womens Health. 2023 Dec 21;15:1981-1997. doi: 10.2147/IJWH.S436624.

DeFranco EA, Lewis DF, Odibo AO. Improving the screening accuracy for preterm labor: is the combination of fetal fibronectin and cervical length in symptomatic patients a useful predictor of preterm birth? A systematic review. Am J Obstet Gynecol. 2013 Mar;208(3):233.e1-6. doi: 10.1016/j.ajog.2012.12.015.

Hezelgrave NL, Shennan AH. Quantitative fetal fibronectin to predict spontaneous preterm birth: a review. Womens Health (Lond). 2016 Jan;12(1):121-8. doi: 10.2217/whe.15.74

Melchor JC et al. Predictive performance of PAMG-1 vs fFN test for risk of spontaneous preterm birth in symptomatic women attending an emergency obstetric unit: retrospective cohort study. Ultrasound Obstet Gynecol. 2018 May;51(5):644-649. doi: 10.1002/uog.18892.

Molina FS et al. Reproducibility and usability assessment of the novel Fine Birth device for threatened preterm labor diagnosis. Am J Obstet Gynecol MFM. 2023 Jul;5(7):100982. doi: 10.1016/j.ajogmf.2023.100982.

National Institute for Health and Care Excellence. Preterm labour and birth (NG25). 2015, last updated 2022. Available from: https://www.nice.org.uk/guidance/ng25

Peebles D. Fetal fibronectin testing in women with threatened preterm labour: a best practice toolkit. London Maternity Strategic Clinical Network, NHS England; 2014. Available from: https://share.google/2exLLi09e6k1DaalW

 

Rubén Molina

Rubén Molina

CEO & Co-founder
Rubén Molina is an entrepreneur and engineer based in Bilbao, Spain, with a background in building engineering, a Master's in Civil Engineering (Structural Engineering), and an AMP from IESE Business School. He currently leads Innitius, a women's health medtech company. Outside of work, he's into functional training and Hyrox, and is a self-confessed coffee lover.